Division (ii) Procedure for Copiers, Digital Duplicators and MFDs without Print Capability
Table 7
TEC Test Procedure — Copiers, Digital Duplicators and MFDs without Print Capability
| Step | Initial State | Action | Record (at end of step) | Possible States Measured |
|---|---|---|---|---|
| 1 | Off | Plug the unit into meter. Zero the meter; wait test period (five minutes or more). | Off energy | Off |
| Testing Interval time | ||||
| 2 | Off | Turn on unit. Wait until unit indicates it is in Ready mode. | — | — |
| 3 | Ready | Copy a job of at least one image but no more than a single job per Job Table. Record time to first sheet exiting unit. Wait until the meter shows that the unit has entered its final Sleep mode. | Active0 time | — |
| 4 | Sleep | Zero meter; wait one hour. If unit turns Off in less than one hour, record time and energy in Sleep, but wait full hour before moving to Step 5. | Sleep energy | Sleep |
| Testing Interval time | ||||
| 5 | Sleep | Zero meter and timer. Copy one job per Job Table. Record time to first sheet exiting unit. Wait until timer shows that 15 minutes have elapsed. | Job1 energy | Recovery, Active, Ready, Sleep, Auto-off |
| Active1 time | ||||
| 6 | Ready | Repeat Step 5. | Job2 energy | Same as above |
| Active2 time | ||||
| 7 | Ready | Repeat Step 5 (without Active time measurement). | Job3 energy | Same as above |
| 8 | Ready | Repeat Step 5 (without Active time measurement). | Job4 energy | Same as above |
| 9 | Ready | Zero meter and timer. Wait until meter and/or unit shows that unit has entered its Auto-off mode. | Final energy | Ready, Sleep |
| Final time | ||||
| 10 | Auto-off | Zero the meter; wait test period (five minutes or more). | Auto-off energy | Auto-off |
Originals may be placed in the document feeder before the test begins. Products without a document feeder may make all images from a single original placed on the platen.