Division (ii) Procedure for Copiers, Digital Duplicators and MFDs without Print Capability

Original text. Later amendments are not shown.

Table 7

TEC Test Procedure — Copiers, Digital Duplicators and MFDs without Print Capability

StepInitial StateActionRecord (at end of step)Possible States Measured
1OffPlug the unit into meter. Zero the meter; wait test period (five minutes or more).Off energyOff
Testing Interval time
2OffTurn on unit. Wait until unit indicates it is in Ready mode.——
3ReadyCopy a job of at least one image but no more than a single job per Job Table. Record time to first sheet exiting unit. Wait until the meter shows that the unit has entered its final Sleep mode.Active0 time—
4SleepZero meter; wait one hour. If unit turns Off in less than one hour, record time and energy in Sleep, but wait full hour before moving to Step 5.Sleep energySleep
Testing Interval time
5SleepZero meter and timer. Copy one job per Job Table. Record time to first sheet exiting unit. Wait until timer shows that 15 minutes have elapsed.Job1 energyRecovery, Active, Ready, Sleep, Auto-off
Active1 time
6ReadyRepeat Step 5.Job2 energySame as above
Active2 time
7ReadyRepeat Step 5 (without Active time measurement).Job3 energySame as above
8ReadyRepeat Step 5 (without Active time measurement).Job4 energySame as above
9ReadyZero meter and timer. Wait until meter and/or unit shows that unit has entered its Auto-off mode.Final energyReady, Sleep
Final time
10Auto-offZero the meter; wait test period (five minutes or more).Auto-off energyAuto-off

Originals may be placed in the document feeder before the test begins. Products without a document feeder may make all images from a single original placed on the platen.

  1. Notes: